Device for determining biologically active points. How does the device for finding acupuncture points work? Product reviews

"Online Store Opt-in-China" - operating 24 hours a day and offering huge selection a variety of products, including electronics, clothing, household goods, cosmetics, etc. Order assembly and dispatch centers are located in Hong Kong and China (Shanghai, Shenzhen).

Why you should choose us:

  • We focus only on the most popular products;
  • We have direct connections with several factories;
  • well-functioning quality control system;
  • constant contact to monitor stock availability;
  • All warehouses are practically close to the goods delivery companies.

Chinese goods wholesale?

So you have come to the right place. Our online store presents Chinese goods and electronics wholesale, such as Cell phones, tablet computers, computer electronics, watches, clothing, and others retail at wholesale prices. Now there is no need to search on the Internet for a tablet that you can also buy from us.

Were you looking for an online clothing store from China? We can help you with this. We have a large catalog of Chinese clothing. Opt-in-China.com is ready to supply both wholesale and retail quantities for your one-page business or online store

site is a Chinese online store that offers only high-quality and inexpensive goods from China. We work 24 hours a day. Cheap products can be ordered by clicking the “Buy” button next to the desired product and delivery can be arranged. Wholesale electronics are delivered to you by mail.

Do you want to buy shoes, clothes, toys, phones, electronics, watches, tablets, spare parts? Here you can find all this for sale at affordable prices.

Purpose

A pen device for identifying and stimulating acupuncture points "Poisk-02" is used to search and accurately determine the location of biologically active points (BAP), as well as for treatment by electrical stimulation to the found points and mechanical stimulation (acupressure) of low intensity.

The movement of the search electrode along the surface of the body is accompanied by a light and sound (acoustic) signal. Correct detection of a point is characterized by a continuous light on the indicator and a continuous sound. As you move away from the acupuncture point, the blinking of the indicator becomes increasingly rare (up to complete disappearance), as well as the sound signal.

The acupuncture device "Search" is recommended for professional use in medical institutions. The product is certified and registered in the state register of medical equipment products Federal service on supervision in the field of health care. Registration certificate No. FS 02012006/3728-06.

Characteristics

The electropuncture device "Search" allows you to accurately determine the location of the active point and at the same time carefully influence it.

The device for finding and electrically stimulating acupuncture points "Search" is a professional medical device suitable for home use. During therapy with this device, no skin damage occurs, so the device is optimal for treating children and people with hypersensitivity.

Can be used during regular reflexology sessions, incl. acupuncture (acupuncture), Su-Jok, etc., as well as for influencing auricular points (points of the auricle).

Unlike many devices of this kind, the Search pen device allows you to remove accumulated static electricity, which makes diagnostics difficult.

Additional benefits

The delivery set includes the book “Healing with Acupressure” (author F.M. Houston), containing an atlas of acupuncture points and recommendations for the prevention and treatment of more than 400 diseases and ailments.

The Search acupuncture device is safe, small-sized, lightweight, easy to use, and has a convenient ballpoint pen shape.

The device is powered by two standard, easily replaceable batteries.

Warranty for the "Search" device: 12 months, inexpensive post-warranty service. Average service life is 5 years.

Acupressure probes


The “Search” point finding device can be additionally equipped with probes for performing mechanical massage (acupressure) on the found points.

For drug-free correction of the body's condition, methods of stimulating biologically active points (BAP) and acupuncture points are widely used. Certain difficulties, especially in the early stages of using this method, are caused by the process of correctly determining the location of BAP on the body.

To date, quite a lot of devices and methods for diagnosing BAP are known. By monitoring the properties of these points, in particular, direct current resistance, it is possible to monitor changes in the state of internal organs and determine the effectiveness of reception medications and carrying out medical procedures, as well as optimizing them. You can observe the dynamics of illness and recovery with a quantitative assessment of the degree of deviation from the normal state and the speed of return to the normal state.

One of the most reliable and visual methods for diagnosing pathology of internal organs is the R. Voll method and its modifications.

In accordance with this method, it is assumed that when measuring the electrical resistance of a certain set of BAPs, it is possible to control changes in the state of these organs using indirect data (changes in electrical resistance). Each vital organ has its own set of BAPs.

It is believed that in the “normal” state of the body, the electrical resistance between acupuncture points (APPs) and the common electrode should be within certain acceptable limits. The greater the value of the electrical resistance of the controlled point, which is responsible for the condition of a certain organ, differs from the permissible value, the more pronounced the pathological process. For example, resistance exceeding the norm corresponds to the development of processes of degradation, aging, extinction of the vital functions of the body, and a decrease in its tone. Reduced resistance suggests the development of inflammatory processes associated with the acute period of the disease. Acceptable resistance values ​​of the controlled point for each specific person are purely individual and determined by his constitution (physique), as well as the electrical conductivity of tissues.

With the help of the devices described below and the development of certain experience, it is possible to diagnose the condition of people, monitor changes in the condition of internal organs during the course of the disease at a quantitative level, and also correct it in a timely manner, monitoring the correctness of the choice medicinal product, choose from a list of various medications the most effective medicine for a particular patient.

In Fig. Figure 24.1 shows a diagram of a device with a dial indicator for diagnosing BAP [Рл 11/97-30]. The device is made on the K122UD1A (K118UD1A) microcircuit. The internal filling of this microcircuit (amplifier) ​​is shown in Fig. 24.2. A comparison of the circuits (Fig. 24.1 and 24.2) shows how much easier the installation of a device can be if it is made not from individual elements, but on the basis of a microcircuit containing ready-made components and elements of a more complex circuit.

A double T-shaped resistive bridge is connected at the input of the differential amplifier (microcircuit). The chains of resistors R1+R2 and R3+R4, with the measuring circuit open, determine the balancing of the circuit (using R2, the arrow of the measuring device is set to zero). The maximum current value (50... 100 μA) through the measuring device frame is limited by resistor R6, and through the measuring circuit by resistor R5.


Rice. 24.2. Analogue of the K122UD1 microcircuit

For a diagnostic device (Fig. 24.1), the maximum voltage drop across the measurement object is about 2 V with a current through the measuring circuit of no more than 10 μA. This device can also be used to measure electrical and non-electrical quantities using appropriate sensors (resistance, voltage, temperature, humidity, light intensity, etc.).

The controlled circuit is connected to the input terminals of the device using common and search electrodes. The common electrode is made in the form of a cylinder of stainless steel or aluminum with a diameter of 15 mm and a length of 60 mm and is clamped in the palm of the person being diagnosed. A search electrode made of wire with a radius of curvature of 0.3...0.4 mm is made of stainless steel, and is touched with measured pressure by a controlled BAP. The resistance of each BAP must be measured at least three times. The entire scale is taken as 100%.

In Fig. Figure 24.3 shows a typical diagram of measurements along 12 classic “energy channels” (meridians), indicated by Roman numerals. They correspond to different internal organs: lungs, large intestine, stomach, spleen and pancreas, heart, small intestine, bladder (genitourinary system), kidneys, pericardium

(vascular system), “triple heater (endocrine system), gall bladder, liver. The specific location of BAP associated with certain organs can be determined from specialized literature. In addition, in the presence of a severe disease, “herald points” can be found independently, experimentally.

To monitor changes in the BAP state (health status) of a small group of people, it is enough to systematically record the results of measurements via controlled channels on a graph (electrical resistance channel date), Fig. 24.3. If the measured value exceeds acceptable limits, it indicates the development or presence of a disease.


A device designed for simultaneous search and stimulation of BAP consists of a pulse generator and a power amplifier (Fig. 24.4) [Рл 9/91-7]. The pulse generator contains an adjustable time-charging RC circuit (R3 and C4). A multivibrator using transistors VT1 and VT2 (KT315) is connected in parallel to capacitor C4 of the RC chain. These transistors operate in reverse mode (with a different polarity of the supply voltage). The bases of the transistors are not connected by direct current to other elements of the circuit. The multivibrator is loaded onto resistor R4. Capacitors C1 SZ, C5 provide positive feedback; Search electrodes are connected in parallel to capacitor C1. The signal from the multivibrator is fed to a power amplifier on transistor VT3 and converted into sound by an electrodynamic head (telephone capsule BF1).

If there is no measurement object (the search electrodes are open), the multivibrator generation frequency is in the ultrasonic region. When the search electrodes are connected to the human body and the subsequent search for BAP, the positive feedback circuit of the multivibrator through capacitors C1 SZ is closed. In this case, the generation frequency sharply decreases due to significant differences from the usual (typical) values ​​of resistance and capacitance of the skin in the vicinity of the BAP. This allows you to confidently identify biologically active points.

If it is necessary to expand the capabilities of the device (to provide an impact on acupuncture points) instead of the telephone capsule, a matching (step-up) transformer is turned on, and active electrodes are connected to its terminals. The positive feedback circuit (search electrodes) is short-circuited, the signal generated by the multivibrator is amplified by a power amplifier on transistor VT3. The generation frequency is varied by changing resistance R3. The signal amplitude can be adjusted by turning on a potentiometer instead of resistor R4. The potentiometer motor is connected to the base of transistor VT3,

The device can also be used as a universal probe of electrical circuits, to study the dynamics of processes occurring in living organisms, to create combined measuring systems “device person”, as a pulse generator for setting up electronic equipment, etc.

The device for searching or stimulating BAP (Fig. 24.5) is a simple ohmmeter [Device “Ledia”, Latvia]. The pointer device PA1 and current-limiting resistors R2 and R3 are connected in series with the power source. At the same time, the described device can be used to influence BAP, while controlling the current strength. Switch SA1 is used to change the polarity of the voltage supplied to the electrodes.

The electroacupuncture stimulator with an ohmmeter (Fig. 24.6), proposed by M. Tsakov and modernized by V. Kozlov, is made on a CMOS microcircuit of the K561LE5 type and a VT1 transistor switch [Рл 10/92-24]. Using capacitor SZ and diode VD4, pulses are generated whose amplitude is close to twice the supply voltage. Switch SA1 allows you to switch the device from BAP search mode to stimulation mode. In the search mode, an ohmmeter on transistors VT1 and VT2 (DC amplifier) ​​is connected to the area of ​​the body being examined. When the electrode touches the BAT, the HL1 LED lights up.


Literature: Shustov M.A. Practical circuit design (Book 1), 2003

The package includes the computer program "Atlas of Acupuncture Points" and the book "Healing with Acupressure: Acupuncture without Needles" (author F. Houston)

Price: 2,800 rub. Free delivery throughout Russia. Payment upon receipt by mail. Buy

Purpose

The device "Poisk-02" is used to search for the location of the center of a biologically active point (BAP), as well as to influence the BAP with weak impulses electric current low frequency or mechanical irritation (pressure) of low intensity.

The use of the Poisk-02 device is an extremely effective and simple method of providing first aid to oneself, as well as a method of self-healing. The generally accepted method of acupuncture in this case is accessible to non-professionals, since it does not require the use of needles, and the finding of the required point is ensured by the device. The method can be used at any time of the day with minimal effort and without material costs.

At the same time, the Poisk-02 device can be used by specialists - doctors to provide medical care in a hospital and on an outpatient basis.

Features of use

Using the Poisk-02 device is extremely simple: when the probe moves along the surface of the body, as it moves away from the center of the biologically active point, the blinking of the indicator LED becomes increasingly rare (up to complete disappearance), and when it hits the center of the BAP, a continuous glow appears.

In the Poisk-02 device, an intermittent sound signal sounds synchronously with the blinking of the indicator light. The presence of a sound signal is indispensable in cases where a person independently uses the device when working with points on the head, back, etc., when it is not possible to observe the light indicator.

After finding the required biologically active point, without changing the location of the probe, the point is treated with weak pulses of low-frequency electric current, as well as acupressure (pressure of the probe). In this case, the electric current flows through the point automatically; no switching between the therapy mode and the mode of finding the point is required.

Additional benefits

During therapy with the Poisk-02 device, a weak electric current flows through a biologically active point. Unlike other electroreflexotherapy devices, which generate mainly “rough” rectangular electric current pulses, the parameters of the electrical impulses of the Poisk-02 device are close to the natural human biocurrent, as a result of which the effectiveness of the procedures is much higher compared to other devices, and there are no possible negative consequences .

The “Poisk-02” device is supplied with the book “Healing with Acupressure: Acupuncture without Needles” (author F. Houston), containing recommendations for the prevention and treatment of more than 400 diseases and ailments.

The “Poisk-02” device is supplied with a computer program “Atlas of Acupuncture Points”, designed to quickly obtain information on the localization and therapeutic indications of acupuncture points. The atlas contains more than 700 acupuncture points. You can search for points by anatomical region, picture, name, index.

The Poisk-02 device can be used simultaneously with traditional reflexology and diagnostic sessions, including acupuncture, Su-Jok, auriculotherapy, Voll, Nakatani diagnostics, etc.

The device is small-sized, safe, easy to use, and has a convenient ballpoint pen shape.

The device is powered by two standard, easily replaceable batteries.

The body of the device and the electrode probe are made of medical stainless steel, a special hygienically clean material that is safe for human skin. There is no skin damage during therapy with this device; The device is also applicable for the treatment of children and people with hypersensitive skin.

Unlike many devices of this kind, the Poisk-02 device allows you to remove accumulated static electricity, which makes diagnostics difficult.

Warranty for the device "Poisk-02": 1 year; post-warranty service; average service life: at least 5 years.

Specifications

Batteries: two elements 393 A GOST 28125-89 (IEC 86-2-87);

Supply voltage: no more than 3 V;

Current consumption in storage mode: no more than 1 µA;

Operating time of the device from one set of batteries: at least a month with daily operation no more than 40 minutes;

Light and sound indication;

Overall dimensions: length: 135 mm; diameter: 16 mm; diameter of conductive probe: 1.0 +- 0.1 mm;

Weight: no more than 100 g.

Indications for use. The Poisk-02 device is most effective in the treatment of functional diseases associated with minor organic changes. Due to the obvious effectiveness, absence of side effects, simplicity, accessibility and high cost-effectiveness of treatment, the use of the Poisk-02 device is indicated for almost all areas of medicine:

Neurology, psychiatry:
alcoholism, insomnia, hypersomnia, headache, dizziness, depression, lumbago, sciatica, neuralgia, neurasthenia, neuritis, obsessive-compulsive neuroses, memory loss, polyneuritis, reactive psychosis, radiculitis (thoracic, lumbosacral), sleep disorders, mental disorders, epilepsy.

Pulmonology, phthisiology:
bronchial asthma, bronchitis, cough, pleurisy, pneumonia, emphysema.

Cardiology:
arterial hypertension, arterial hypotension, arrhythmias, myocarditis, Raynaud's disease, angina pectoris, paroxysmal tachycardia, extrasystole, obliterating endarteritis, rheumatic carditis.

Gastroenterology:
gastric atony, gastritis, gastroduodenitis, bile duct dyskinesia, dyspepsia, gastroenteritis (acute), hepatitis, cholelithiasis, chronic constipation, heartburn, hiccups, colitis, flatulence, intestinal obstruction, obesity, prolapse of the stomach, belching, chronic pancreatitis, postoperative intestinal paresis , chronic diarrhea, vomiting, spasms of the stomach and esophagus, cholecystitis, enteritis, enterocolitis, peptic ulcer.

Surgery:
rectal prolapse, skin gangrene, hemorrhoids, mastitis, carbuncle, erysipelas, anal fissure, phlegmon.

Arthrology, traumatology:
arthralgia, rheumatoid arthritis, arthrosis, pain in the lower leg, ankle joint, hand, knee joint, elbow joint, pubic joint, wrist joint, neck area, shoulder joint, spine, foot, dislocations, osteomalacia, bursitis, periarthritis of the humerus, sprain, noise and friction syndrome in joints, synovitis, thickening of the spine.

Ophthalmology:
astigmatism, optic nerve atrophy, blepharitis, blepharospasm, myopia, glaucoma, hyperopia, keratitis, conjunctivitis, strabismus, optic neuritis, thermal eye burn, decreased twilight vision, recurrent juvenile retinal periphlebitis, retinitis, spasm of the central retinal artery, barley.

Otorhinolaryngology:
anosmia, laryngitis, nosebleeds, otitis, rhinitis, sinusitis, tonsillitis, tubo-otitis, hearing loss, pharyngitis, tinnitus, Meniere's disease, swelling of the uvula of the soft palate, hoarseness.

Endocrinology:
gynecomastia, hypothyroidism, pituitary cachexia, pituitary insufficiency, diabetes, dysregulation of endocrine glands, thyrotoxicosis.

Infectious diseases:
chickenpox, hepatitis, influenza, dysentery, whooping cough, malaria, mumps.

Dentistry:
arthritis of the temporomandibular joint, gingivitis, glossitis, toothache, trigeminal neuralgia, periodontal disease, chronic parenchymal parotitis, periodontitis, chronic interstitial sialadenitis, temporomandibular joint pain dysfunction syndrome, stomatitis.

Urology:
hematuria, impotence, ischuria, urinary incontinence, acute nephritis, nephropathy, orchitis, pyelonephritis, pollakiuria, kidney stones, prostatitis, urethritis, cystitis.