Heating elements and electrode boilers: principle of operation, advantages and disadvantages

There are currently on the market a large number of heating equipment that runs on various fuels. The most reliable and simple are electric models. Consider electric heating elements and electrode boilers. TEN boilers are externally attractive equipment that provides for wall installation, ease of installation and compact dimensions. They have start-up and thermostatic fittings that maintain the required temperature in ... read more >

Electric boilers

Electric boilers are modern heating boilers that use electricity as fuel. Electric boilers are used both for equipping private houses and for heating on commercial facilities, that is, according to their purpose, they are divided into household and industrial boilers heating. The use of electric boilers is relevant where power outages rarely occur and where there is enough power for the normal operation of electric boilers, since ... read more >

Choosing a heating boiler

Heating boilers are stationary devices that generate heat energy during fuel combustion. Developed by them thermal energy is transferred to a liquid carrier (water), hence another name arises - hot water boilers. Heating boilers differ in the types of fuel on which they operate. There are electric, gas, solid fuel, diesel, as well as combined heating boilers. Depending on the purpose, heating boilers are divided into: single-circuit, which ... read more >

Which boiler is better

It is probably impossible to unequivocally answer the question which boiler is better. For people with different incomes, under different operating conditions, they are suitable, like completely different boilers, and, possibly, the same units. It's good that in our time there is a fairly wide choice, just before settling on the final version, you need to carefully familiarize yourself with the assortment and consult with specialists. At the same time, one must be prepared for the fact that each of ... read more >

How to choose a boiler

In order to choose the best boiler for your own home, you need to know what boilers are, and follow a few simple rules, allowing you to choose the best option for specific conditions. So, boilers for heating and hot water supply are single-circuit and double-circuit, they can work on various types fuels, be made from iron or steel, differ in cost and manufacturers, and have other strengths and weaknesses of their own. Single-circuit boilers… read more >

steam boilers

A steam boiler is a heating unit designed to create saturated or superheated steam and heat water by burning fuel and converting chemical energy into thermal energy. Steam boilers can operate on gas, liquid and solid fuels. There are low pressure steam boilers and high pressure steam boilers. Their design is characterized by reliability and durability. Low pressure steam boilers can be used in the food industry for cleaning… read more >

The electric boiler of the GALAX series belongs to devices operating in closed-type heating systems with forced circulation of the coolant with the recommended most economical mode - the temperature at the boiler inlet is 35-45 ° C. The boiler operates in automatic mode with minimal maintenance. The device is equipped with systems that protect against accidents of heating wiring:

  • coolant flow monitoring system,
  • safety valve.
The boiler also has circulation pump, pressure gauge and automatic air release valve.
For boilers of the economy series, only a pressure gauge and an automatic zozi-ear outlet valve are installed in the hydraulic part.
Modern electronic system control system ensures reliable operation in automatic mode, simple maintenance and a high level of thermal comfort in heated rooms. The control system provides for the connection of external devices for controlling the air temperature in the room.
The power supply of the boilers is carried out from a 3-phase AC network with a solidly grounded neutral voltage of 380 V, frequency of 50 Hz. The quality of electricity must comply with GOST R54149-2010.
The boiler body has a degree of protection IP40 according to GOST 14254-96, climatic version UHL4 according to GOST 16350.
Class of protection against electric shock 1 according to GOST 27570.0-87. For normal operation of the boiler, the following conditions are necessary:
  • the temperature of the room in which the boiler is installed, the maximum temperature is from + 70 ° С to + 40 ° С; working - from +100 to +35°С, if there are no other requirements;
  • relative air humidity at 20°C - no more than 75%;
  • environment- not explosive, not containing corrosive gases and vapors that destroy metal and insulation, as well as industrial dust, in quantities that destroy or disrupt the operation of the boiler.
The heat carrier used is any for heating systems with pH = 6.5-8.5. You can use ordinary drinking water San PiN2.1.4.559-96, distilled, melted snow, rain, (filtered), non-freezing glycol coolants or their mixture-1 with a freezing point of at least -40 ° C. The maximum allowable pressure in the heating system before the emergency valve is activated is 3 bar.
Mode of operation - long.
Specifications for boilers - TU3468-005-17289826-13

Main technical data of boilers GALAX

Feature/Model GALAX 9 GALAX 12 GALAX 15 GALAX 18 GALAX 21 GALAX 24 GALAX 27 GALAX 30
The volume of the heated room, up to (m3) 225 300 375 450 525 600 675 750
Rated input power (kW) 9 12 15 18 21 24 27 30
Boiler rated current for each phase, frequency 50 Hz (A) 13,7 18,2 22,7 27,3 31,8 36,4 40,1 45,5
Cross-section of the current-carrying copper core of the connection wire, not less than (mm2) 5x2.5 5x4 5x4 5x6 5x6 5x6 5x10 5x10
Cross section of current-carrying copper core of ground wire, not less than (mm2) 4 6 6 6 6 6 10 10
Boiler weight without coolant, net (kg) 26,5 26,5 26,5 27 27,5 27,5 28 28
DN pipes for connecting the boiler to heating system G 1"
Overall dimensions (height x width x depth) (mm) 600x450x200
Permissible pressure before actuation of the emergency pressure valve, bar 3

In accordance with clause 3.2.1 and clause 4.1.1 of GOST 33863-2016 “Energy efficiency. Equipment for heating. Energy Efficiency Indicators and Methods of Determination”.

Efficiency 98 ≤ s< 125 GOST 33863-2016 complies with the provisions of the Commission Regulation of the European Union of February 18, 2013 811/2013/EU*, supplementing Directive 2010/30/EU of the European Parliament and of the Council regarding the energy labeling of space heaters.

SAVE FROM 40% ON ELECTRICITY BILLS

When using the electrode boiler "Galan" in comparison with any heating element boiler of any manufacturer.

Maximum economy and safety

Case design (heating elements and automation in one case) in contrast to the modular (separate) design.
Can be used in conjunction with RCD 30 mA (N and PE separated).
Possibility of use in systems "heat-insulated floor". The presence of a built-in relay that allows you to automatically enter the boiler into operation after a long power outage.

2 basic modifications:

Single-circuit boiler GALAX G 105

Work only on the heating circuit.

  • The presence of a built-in ammeter, which greatly simplifies commissioning and subsequent maintenance (up to remote technical support and consultations on the federal number 8-800-200-1681).
  • The presence of a built-in current protection relay (I), set at the factory to the maximum allowable rated power of each boiler, which eliminates the operation of the circuit breaker in case of possible emergency situations.
  • Possibility, if necessary, to safely adjust the power of the boiler to the required heat balance of the heated room.
  • The boiler includes a built-in automatic air vent and safety valve(3 bar).
  • Two executions - with the built-in pump and without.

Double-circuit boiler GALAX G 352

Ability to work in 2 modes:

  1. only for the heating circuit;
  2. to the heating circuit and hot water supply (DHW) when using an indirect heating boiler with an additional circulation pump.

The presence of built-in current protection (I), set at the factory to the maximum allowable rated power of each boiler, which eliminates the operation of the circuit breaker in case of possible emergency situations.

  • Display and adjustment of heating temperature and DHW temperature. Current current and pressure indication.
  • Possibility of use without additional devices of preferential tariffs in the presence of 2 or 3 tariff meters.
  • The boiler includes a built-in automatic air vent (AVK), a safety valve (3 bar) and a pressure gauge.
  • Description
  • Characteristics
  • Reviews ()
  • Shipping and payment
  • Return and exchange

Description of the Galan Galax 6 electrode boiler with a pump

The Galax electrode boiler is a precisely calculated, self-adjusting device for the required power consumption. When the coolant is heated, its electrical resistance decreases. Electricity passing through the electrodes increases, correspondingly increases the power consumption. The boiler begins to gradually gain electrical power and give it in the form of heat to the coolant. The total power consumption will depend on the temperature of the coolant set by the consumer and its quantity.

The process of heating the coolant in the Galax electrode boiler occurs due to its ionization, i.e. the process of heating the coolant goes directly, without an "intermediary" (for example, a heating element).

Optionally, you can separately buy automation, which will allow you not only to set the desired temperature of the radiators or the air temperature in the room, but also automatically maintain it around the clock, turning the boiler on and off.

H It does not require approval for installation from the boiler supervision authorities ("Rules for the Design and Operation of Electrode Boilers").

The manufacturer reserves the right to change the country of production, the characteristics of the product, its appearance and completeness without prior notice to the seller. Specify information from managers!

Specifications Galan Galax 6 with pump

Rated power 6 kW
Rated voltage 220 / 380 V
Rated current frequency 50 Hz
Rated current of the circuit breaker at a voltage of 220 V 32 A
Rated current of the circuit breaker at a voltage of 380 V 3x10 A
Recommended coolant volume 30-60 l
Heated area up to 90 m²
Cross-section of the current-carrying copper core of the connection wire at 220/380 V at least 6 / 2.5 mm²
Protection class against electric shock 1
Execution according to the degree of protection against moisture IP X W splash-proof
Connection to the heating system coupling DN 32 mm
Boiler dimensions 600x450x230 mm
Boiler weight (with/without pump) 19.4 / 16.9 kg

1. Delivery methods

Passenger transport

Freight transport

(oversized)

Postamata and PVZ Post office
Moscow 500 rub from 1700 rub** 200 rub
MO, region 500 rub*

from 1700 rub*

200 rub 500 rub
Regions, RF 350 rub 500 rub
Pickup Issuance of goods until 18:00, Ramensky district, Mikhailovskaya Sloboda, Staroryazanskaya street, 4. (upon payment - goods reserve 3 days)

* each 1 km outside the Moscow Ring Road additionally 20 rubles (passenger transport) or 50 rubles (freight transport)

** For full information on the delivery of oversized cargo, see the section